SUP-72 Inductively Coupled Plasma-Mass Spectrometer ICP-MS

Item No.: YSUP-72-4028
SUP-72 inductively coupled plasma-mass spectrometer ICP-MS is a high-sensitivity, rapid food detection and ultra-trace analysis instrument, automatic.
Product parameters
Product Name: Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
Model Number: SUP-72
Brand: E.P.C
Minimum Order Quantity: 1 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
Price: The price is determined according to the parameters and quantity of the order.
Supply Ability: 8 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS ) per month
Place of Origin: China
INQUIRY
Description
SUP-72 inductively coupled plasma-mass spectrometer ( ICP-MS ) is a high-sensitivity, rapid food detection and ultra-trace analysis instrument, fully automatic. Dozens of elements and isotopes can be detected in one go.
SUP-72 ICP-MS can meet the demanding analytical needs of scientific research, as well as strict third-party testing requirements.
 

Working Principle of Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)
To understand the working principle of inductively coupled plasma-mass spectrometer, please see the "Principle of Inductively Coupled Plasma-Mass Spectrometer".
 

Features of SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
The SUP-72 Inductively Coupled Plasma-Mass Spectrometer has fast analysis speed, high sensitivity and excellent interference elimination effect. Specialized design makes the application easier.
 
Excellent Sensitivity
The aerodynamic simulation design is used at the junction of the high temperature plasma and the high vacuum mass spectrometer inlet, and it is improved from the previous model. The optimized ion interface (optimized double cone structure) enables the SUP-72 ICP-MS to have a higher sensitivity of 350Mcps/ppm or better. Its detection limit as low as sub-ppt is more suitable for analysis of scientific research and third-party testing.
 
Excellent Ability to Cancel Interference
• The improved collision/reaction cell adopts the waterfall flow distribution air inlet method, so that He is introduced into the cell orthogonally throughout the whole process, forming a good gas distribution. Only 30% of the airflow can achieve the same effect as other collision/reaction cells, greatly improving the efficiency of collision reaction.
• Ion deflection system and high-precision quadrupole mass analyzer effectively eliminate interference factors in detection.
 
Adaptability to a Variety of Gas Paths
SUP-72 ICP-MS can be expanded to configure seven working gases (including diluent gas, hydrogen, helium, etc.), with better adaptability to meet the analysis needs of various complex and extreme conditions.
 
Lower Running Costs
The low-power standby mode of the instrument greatly reduces the consumption of argon gas and electricity without turning off the flame, saving costs.
 
Excellent Performance of Substrate Resistance
Aerodynamically simulated ion interface, high-efficiency ion deflection system, patented collision / reaction cell, self-excited all-solid-state ICP ion source, and argon on-line dilution system (AGOD) ensure that SUP-72 has excellent performance of substrate resistance, 10 % of high-salt samples can be injected directly.
 
SUP-72 ICP-MS for Special Applications
● Fully automatic heavy metal analysis system that can meet the detection of laboratory membrane, soil, etc.
● On-line monitoring system for heavy metals in surface water
● Online monitoring system for atmospheric heavy metals for atmospheric particulate matter
● Heavy metal speciation analysis system based on LC-ICP-MS
● Solid direct injection ICP-MS solves the analysis of solid refractory samples
● On-line monitoring system for hydrometallurgy process
● Metal element online monitoring system for impurity detection in semiconductor high-purity reagents
● On-line monitoring system for radionuclides in hazardous locations
 
LC-ICP-MS System Designed for Speciation Analysis
SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )16-LC-ICP-MS System Designed for Speciation Analysis
• Large cone hole ensures salt tolerance.
• Inverter power conditioner guarantees power supply resistance to organics (100% methanol).
• Efficient collision / reaction cell + KED to remove mass interference.
• The friendly Element V software platform realizes the linkage control and interlock protection of LC and ICP-MS in the same set of software.
• A program package for the analysis of organic mercury/tin/lead/arsenic species and chromium valence methods is available.
• Can be configured with HPLC or UPLC to meet the analysis requirements of various forms and valence states.
 
Solid Direct Sampling-ICP-MS Combination System
• Based on the combination of graphite furnace electrothermal evaporation technology and ICP-MS technology, the solid samples can be directly injected and analyzed without digestion. The analysis efficiency is greatly improved. It is a typical green analysis technology.
• Based on the direct dissociation technology of high-temperature solid samples in graphite furnace, it is especially suitable for various conventional difficult-to-analyze samples such as insoluble, difficult to digest, organic and soil samples.
• High temperatures up to 3000°C dissociate all samples. Through PID infrared temperature control technology, the temperature control and temperature program function are perfectly realized, which is suitable for the analysis of different elements of different samples.
• Combined with AGOD argon online dilution system, it can effectively eliminate the influence of matrix and improve the analysis precision.
 
Collision mode + KED to resolve the interference of polyatomic ions
Polyatomic ions from solvents and samples may interfere with test results. The SUP-72 ICP-MS is equipped with a new hexapole collision/reaction cell system and operates in KED mode to eliminate these interferences.
The working principle of kinetic energy discrimination (KED): as shown below. In the collision/reaction cell, initially, the analyte (V) and the polyatomic interfering ions (CL, O) lose the same energy per collision with the He atoms. However, the interfering ions (CL, O) are larger than the test ions (V) and have more collision opportunities. When they reach the exit of the cell, the kinetic energy of the analyte (V) and the interfering ions (CL, O) are no longer the same due to the number of collisions. The interfering ions are blocked by the potential well voltage at the entrance of the latter quadrupole due to the large kinetic energy loss, and cannot enter the latter quadrupole mass analyzer.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )18-Collision mode + KED to resolve the interference of polyatomic ions
After those polyatomic interfering ions are eliminated, the detection limit of ICP-MS is greatly improved.
 
Computer Workstation Simplifies Complex Detection and Analysis
SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
• System software supports HPLC coupling. It creatively realizes the functions of instrument reverse control, chain protection, automatic peak finding and automatic/manual integration under the same interface.
• Chinese and English interface, easy to learn and use.
• Customized report output
• Visual operation monitoring
SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
• Real-time display of key operating parameters
• Plasma work adopts chain protection (argon gas, cooling water, exhaust air, torch chamber, waste liquid, temperature)
 

Structure of SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)
SUP-72 Inductively Coupled Plasma-Mass Spectrometer Structure Diagram
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)2-SUP-72 Inductively Coupled Plasma-Mass Spectrometer Structure Diagram

Description of the Structure of the SUP-72 Inductively Coupled Plasma-Mass Spectrometer
① High-efficiency Sampling System
Detachable Torch Tube
The detachable torch tube is easy to assemble and disassemble. It only needs to replace the central tube to meet the injection requirements of organic, high salt, high sensitivity, and HF acid resistance.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)3-Detachable Torch Tube

TEC Refrigerated Sampling Unit
The TEC sampling unit is a refrigeration cyclonic spray chamber of standard configuration, improves the continuous work stability and organic solvent analysis capability of the instrument, and reduces the oxide yield.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)4-TEC Refrigerated Sampling Unit

Full MFC Gas Control System
It adopts a highly integrated and high-precision digital MFC gas circuit controller, with a control accuracy of <0.5%. It can be configured with up to seven MFC channels. In addition to atomizing gas, auxiliary gas and cooling gas, additional dilution gas, auxiliary oxygen, Two-way collision gas, etc.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)5-Full MFC Gas Control System

Argon On-Line Dilution System (AGOD)
It can inject regular samples as well as complex samples with high salt. When injecting complex samples with high salt, a second argon flow is added between the spray chamber and the torch tube to dilute the sample aerosol before entering the torch tube, reducing the total amount of sample entering the plasma. Direct analysis is possible without adding any diluent solution. The analysis results are stable and accurate.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)6-Argon On-Line Dilution System (AGOD)

12 Rotor High Precision Injection Peristaltic Pump
Standard configuration of 12 rotor high precision peristaltic pump, it can be configured with pump tubes of various materials such as PVC, Solva, Tygon, Viton, etc., to meet the needs of routine injection, organic solution injection, and long-life mode. The pump tube with a flared nozzle can be selected, which greatly reduces the difficulty of use.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)7-12 Rotor High Precision Injection Peristaltic Pump


② Stable ICP Ion Source
Patented Self-excited All-solid-state ICP Ion Source
The patented self-excited all-solid-state RF power supply adopts frequency matching tuning and has a high tuning rate. Organic samples can be analyzed directly without moving parts, which are stable and reliable. It is driven in balance to achieve ion kinetic energy balance without the need for a shield torch.
● No need for matching box, fast frequency conversion in milliseconds to match plasma load changes, and it is not easy to flame out.
● Matrix tolerance is improved. For example, in arsenic speciation analysis, buffer salts can be injected directly.
● Ability to analyze volatile organic solvents, such as: 100% acetonitrile, 100% methanol.
● Balanced drive reduces ion kinetic energy dispersion and secondary ion generation without shielding ring.
● Water cooling to ensure long-term stability.
● “Istandby” standby mode, low argon consumption
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)8-Patented Self-excited All-solid-state ICP Ion Source
 
"Istandby" Standby Mode with Low Argon Consumption
During the suspension of analysis work, the instrument automatically standby with low power, greatly reducing the consumption of argon gas and electricity. When the sample is injected and analyzed, it will automatically return to normal working conditions.
 

③ Reliable Double Cone Ion Interface
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)12-Reliable Double Cone Ion Interface
The improved double-cone interface perfectly realizes the transition from ICP ordinary working atmospheric pressure to MS high vacuum, effectively reducing the load of MS vacuum pump. Efficient extraction and transfer of representative ions is achieved in the transition from the ultra-high temperature of the ICP ion source to the ambient operating temperature of the MS. Interface technology with two working modes, cone material is nickel or platinum material, optional.
• "High Sensitivity Mode" for high throughput analysis
• "High salt tolerance mode" can ensure long-term working stability
 
With the Help of Aerodynamic Simulation
● Optimized the two-cone design, greatly improving the performance of the instrument.
● Reduces salt deposition and improves substrate tolerance.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)9-With the Help of Aerodynamic Simulation

Extraction Lens
● Any voltage from -200 to +5V can be applied, and the extraction voltage can be adjusted arbitrarily for different ions and sample matrices.
● Positive voltage can completely isolate ions, preventing ions from entering the ion optical system and causing unnecessary pollution during standby.
 
Easy Handle Change Cone System
● Innovative handle-type cone changing system has interlock protection device to prevent abnormal operation.
● Replacing the cone is simple, allowing easy cone replacement and maintenance without breaking the vacuum.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)10-Easy Handle Change Cone System


④ Ion Deflection System
Schematic diagram of ion deflection transmission (schematic diagram of eliminating detection interference)
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)11-Schematic diagram of ion deflection transmission (schematic diagram of eliminating detection interference)
The ion deflection system consists of the first deflection lens, the collision / reaction cell and the second deflection lens. As shown in the figure above, ions and other particles move from right to left through the small hole in the middle of the double cone under the action of the extraction lens. Under the action of the first deflection lens, the ions are turned off-center. At this time, the photons that can only go straight are blocked and cannot reach the detector (to prevent photon interference). Likewise, neutral particles that can only go straight are received by the receiver and cannot reach the detector (to prevent neutral particle interference). Under the action of the deflecting lens, the electrons travel a different path than the ions, so they are separated and cannot reach the detector. After the ions turn off-center, they reach the collision/reaction cell. The polyatomic interfering particles are removed by a collision / reaction cell. The ions then turn under the action of the second deflection lens, return to the central axis, continue their journey, and reach the quadrupole mass analyzer....
 
High Efficiency Ion Deflection System (Ion Optical System)
● Two-cone interface for efficient transmission of analytical ions.
● Twice before and after deflection to achieve effective elimination of interfering particles (neutral particles, electrons, photons).
● Patented collision / reaction cell technology, distributed air intake system to minimize interference
● Pure molybdenum quadrupole mass analyzer, the most stable choice for high-resolution mass spectrometry.
● Dual-mode discrete dynode detector, with a dynamic range of 9 to 10 orders of magnitude
 
Open Ion Deflection Lens
● Large aperture first deflection lens maximizes the ions transmission rate and improves sensitivity.
● Special neutral particle receiver, and deflecting lens that requires no replacement and cleaning
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)13-Open Ion Deflection Lens


⑤ High-speed Dynamic Collision / Reaction Cell
● The SUP-72 is equipped with a new hexapole collision/reaction cell system, which greatly enhances the efficiency of collision and interference elimination while maintaining high ion transmission capacity.
● This is a collision / reaction cell with a compound electric field, which is small in size and has high ion transmission efficiency.
● The patented gas diffusion method makes the gas diffusion of "collision/reaction" uniform, which greatly improves the collision efficiency and sensitivity.
●Ion kinetic energy discrimination technology (KED) is adopted to provide excellent interference removal capability.
●It can realize direct dilution and injection of blood/serum samples, with good anti-interference effect.
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)14-High-speed Dynamic Collision / Reaction Cell


⑥ High-precision Quadrupole Mass Analyzer
SUP-72 Inductively Coupled Plasma-Mass Spectrometer (ICP-MS)15-
• The quadrupole mass analyzer made of pure molybdenum material has high thermal stability.
• Dual-channel radio frequency power (RF) has self-adaptive adjustment function to ensure good stability under normal laboratory conditions.
• Mass axis calibration without manual tuning.
 

⑦ High Sensitivity Electron Multiplier
Proprietary digital/analog dual-mode detector (dynode detector) with a dynamic range of 9 to 10 orders of magnitude.
 

Technical Parameters of SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
The technical parameters of SUP-72 ICP-MS should be determined according to the following conditions of the user:
• Field of application of the instrument
• Testing substance species and automatic sampling system
• Determination of detection and quantification limits
• The technical indicators of SUP-72 ICP-MS can meet or exceed the standards of GB 5009.268----2016.

We can provide solutions of detection technology for users' reference.
 
Application Example of SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )
GB 5009.268----2016, National Food Safety Standard, Determination of Multielements in Food, Method 1 Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
SUP-72 Inductively Coupled Plasma-Mass Spectrometer can meet or exceed the quality requirements of GB 5009.268----2016.
 

The training base can provide technical support for the employees of the enterprise and users
SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )21-
Our technical support includes long-distance video guidance on the Internet, user training at the company's training base, technical support from our technicians at the user testing site, and technical services from local dealers.
 

Making Site for the SUP-72 Inductively Coupled Plasma-Mass Spectrometer
SUP-72 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS )22-Making Site
Before you decide to purchase the instrument, we recommend that you come to visit the production workshop and take a look at the precision machining equipment of the instrument. Bring you direct access to the source of production, more real understanding of product performance and ex-factory price. "If the manufacturer is good, you will know when you look at the production site."
 
-------------------------------------------

Related Products
If you need other types of products, please click on the blue font below, you can browse another page to see the related introduction.
1. SUP-70 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS): can detect dozens of elements and isotopes at one time, ultra-trace analysis, automatic.
2. SUP-70M Vehicle-mounted Inductively Coupled Plasma-Mass Spectrometer: can detect dozens of elements and isotopes in one-time ultra-trace, anti-vibration.
3. SUP-735 Inductively Coupled Plasma-Mass Spectrometer ( ICP-MS /MS, ICP-QQQ ): is a space tandem multi-stage quadrupole mass spectrometer equipped with an inductively coupled plasma.
4. Microbiology Testing Equipment and Instruments: include incubators, gadgets, and instruments, are one of the food safety testing equipment.
5. Laboratory Equipment and Instruments: include precision weighing equipment, evaporators, drying ovens and food testing instruments.
6. Food Production Monitors and Online Detectors: are capable of detecting and monitoring the quality of each product on the food production line, is important testing equipment.

Note
•If the products you need are not listed on this website, you can also Contact Us, you maybe get a satisfactory answer.
•If the products performances and parameters required by the customer are beyond the scope of this introduction, we can customize it specially.
•The products performances and parameters may be modified at any time without notice.
•The final performance and parameters of the products are determined by the contract signed by the customer at the time of order.
-------------------------------------------